HydroConnect

Acumulador ACS

Double buffer tank

HydroConnect

HydroConnect 180+75 is the combination of a 75 litres buffer tank and a 180 litres DHW tank in a single compact unit. It includes different connections located on the top to connect it to the DHW system, the air conditioning system and the heat pump or chiller (aerothermal, geothermal, etc.), for easy and quick installation.

Savings up to:
0%
Fácil instalación

EASY INSTALLATION

HydroConnect incorporates different Plug & Play outputs located on the top for quick and easy installation.

100% Adaptable

100% ADAPTABLE

This combined buffer tank is specifically designed to be combined with a heat pump (air source heat pump, geothermal heat pump, etc.).

Máxima calidad

DURABILITY AND SAFETY

Made from high quality materials, it guarantees a long service life, maintaining safety standards at all times.

SAVE SPACE

A single device for storing air conditioning and DHW water, avoiding the need to install multiple tanks or systems.

Double operation

Unlike a conventional inertia tank, HydroConnect can store hot water and water used for heating.

Thanks to the incorporation of different outputs located on the top of the equipment, it can be easily connected to the DHW system, the air conditioning system and the heat pump or chiller (aerothermal, geothermal, etc.), making its installation much simpler and faster.

Discover the differences between a conventional buffer tank and Efitherma’s HydroConnect:

Tank for DHW and air conditioning

HydroConnect is designed to be quick and easy to install, requiring fewer connections than a traditional system with separate tanks. It also operates with an efficiency oriented approach, reducing energy consumption and the costs associated with the production of DHW and air conditioning.

The differences with respect to a conventional inertia tank are many, some of the most notable are: it’s dual functionality and multiple applications.

It’s stainless steel tanks, together with the titanium electronic anode against impressed current corrosion, ensure greater durability and efficiency in its operation. It also includes protection against legionella bacteria to ensure the healthiness of the stored water.

Efficiency and savings

With titanium anode

Anti-Legionella System

Stainless steel tanks

Tank capacities

ACS + AIR CONDITIONING

Technical Data

HydroConnect 180 + 75 Liters​

Technical data of the equipment

Surface of the inner coil

9 m²

Máx. Temp. DHW Storage

80 ºC

Max. pressure of the DHW safety valve

6 bar

Max. pressure buffer tank safety valve

3 bar

Capacity of the DHW expansion vessel

5 Liters

Type of tank insulation

Injected polyurethane

Connections and dimensions

Hydraulic connection inlet/outlet heating

1” Female

Hydraulic connection inlet/oulet heat pump

1” Female

Hydraulic connection inlet/outlet of the tank

3/4” Female

Equipment height

1925 mm

Equipment width

594 mm

Equipment depth

609 mm

More Options

Recommended alternatives

Domestic Hot Water Heat Pump

AQ-Pro Series

Aerothermal / Domestic Hot Water

Know more
Domestic hot water and ventilation

AQ VENT

Ventilation + Domestic Hot Water

Know more
Exhaust Air Heat Pump

AQ BiVent

Ventilation + Domestic Hot Water + Heating

Know more
Bomba de calor híbrida

2Water Hybrid

Electricity + Domestic Hot Water

Know more
Bomba de calor termidinamica

AQ-TD

Thermodynamics / Domestic Hot Water

Know more
AQ Lite Carrusel

AQ Lite

Retrofit Heat Pump / Domestic Hot Water

Know more
AQ Lite-TD Carrusel

AQ Lite-TD

Retrofit Heat Pump / Domestic Hot Water

Know more

HydroConnect

HydroConnect 180+75 is the combination of a 75 litres buffer tank and a 180 litres DHW tank in a single compact unit. It includes different connections located on the top to connect it to the DHW system, the air conditioning system and the heat pump or chiller (aerothermal, geothermal, etc.), for easy and quick installation.

Savings up to:
0%
Acumulador ACS
Fácil instalación

Easy installation

It incorporates different Plug & Play outputs located on the top for quick and easy installation.

Máxima calidad

Durability

Made from high quality materials, it guarantees a long service life, maintaining safety standards at all times.

100% Adaptable

100% Adaptable

This tank is specifically designed to be combined with a heat pump (aerothermal, geothermal, etc.).

Save space

A single device for storing air conditioning and DHW water, avoiding the need to install multiple tanks or systems.

Double operation

Unlike a conventional inertia tank, HydroConnect can store hot water and water used for heating.

Thanks to the incorporation of different outputs located on the top of the equipment, it can be easily connected to the DHW system, the air conditioning system and the heat pump or chiller (aerothermal, geothermal, etc.), making its installation much simpler and faster.

Discover the differences between a conventional buffer tank and Efitherma’s HydroConnect:

Tank for DHW and air conditioning

HydroConnect is designed to be quick and easy to install, requiring fewer connections than a traditional system with separate tanks. It also operates with an efficiency oriented approach, reducing energy consumption and the costs associated with the production of DHW and air conditioning.

The differences with respect to a conventional inertia tank are many, some of the most notable are: it’s dual functionality and multiple applications.

It’s stainless steel tanks, together with the titanium electronic anode against impressed current corrosion, ensure greater durability and efficiency in its operation. It also includes protection against legionella bacteria to ensure the healthiness of the stored water.

Efficiency and savings

Titanium anode

Anti-Legionella system

Stainless steel tanks

More Options

RECOMMENDED ALTERNATIVES

Domestic Hot Water Heat Pump

AQ-Pro Series

DHW

Know more
Domestic hot water and ventilation

AQ VENT

Ventilation + DHW

Know more
Exhaust Air Heat Pump

AQ BiVent

DHW + Vent. + Heat.

Know more
Bomba de calor híbrida

2Water Hybrid

Electricity + DHW

Know more
Bomba de calor termidinamica

AQ-TD

DHW

Know more
AQ Lite Carrusel

AQ Lite

Retrofit / ACS

Know more
AQ Lite-TD Carrusel

AQ Lite-TD

Retrofit / DHW

Know more

EFI SmartApp

Control your equipment from the APP

Edit Content
  • Ciclo de extracción
  • Potencia nominal ACS (14ºC) *
  • Consumo nominal (14ºC) *
  • SCOP ACS (14ºC) *
  • Potencia térmica sistema de apoyo
  • Gas refrigerante
  • XL
  • 1543w
  • 516w
  • 2,99
  • 1500w
  • R134a

* Datos expresados para una temperatura de calentamiento de 55ºC y temperatura de agua fría de 10ºC según la norma UNE-EN16147

* SCOP según la zona climática

Edit Content
Click on the Edit Content button to edit/add the content.
Efitherma
Efitherma